在BioDeep NovoCell知识数据库中,参考离子总共被划分为4个级别。
  • Confirmed: 这个参考离子已经通过手动审计得到确认和验证。
  • Reliable: 这个参考离子可能在特定的解剖组织环境中高度保守。
  • Unreliable: 这个参考离子具有较高的排名价值,但缺乏可重复性。
  • Unavailable: 由于排名价值低且缺乏可重复性,这个参考离子不应用于注释。

Found 16 Reference Ions Near m/z 711.4858
NovoCell ID m/z Mass Window Metabolite Ranking Anatomy Context
MSI_000006095 Reliable 711.4915 711.4913 ~ 711.4918
MzDiff: 2.1 ppm
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
17.97 (100%) Rattus norvegicus
[UBERON:0004358] caput epididymis
MSI_000061483 Reliable 711.4916 711.4915 ~ 711.4919
MzDiff: 1.8 ppm
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
2.38 (100%) Mus musculus
[UBERON:0000956] cerebral cortex
MSI_000058599 Unreliable 711.4918 711.4916 ~ 711.492
MzDiff: 1.6 ppm
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
2.21 (100%) Mus musculus
[UBERON:0001950] neocortex
MSI_000002447 Unreliable 711.4921 711.4921 ~ 711.4921
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
1.23 (100%) Rattus norvegicus
[UBERON:0001950] neocortex
MSI_000003166 Unreliable 711.4921 711.4921 ~ 711.4921
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
1.56 (100%) Rattus norvegicus
[UBERON:0002037] cerebellum
MSI_000005300 Unavailable 711.4921 711.4921 ~ 711.4921
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
-0.88 (100%) Rattus norvegicus
[UBERON:0002298] brainstem
MSI_000005978 Unavailable 711.4921 711.4921 ~ 711.4921
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
-1.14 (100%) Rattus norvegicus
[UBERON:0002435] striatum
MSI_000027072 Unreliable 711.4945 711.4945 ~ 711.4945
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
1.77 (100%) Mus musculus
[UBERON:0002048] lung
MSI_000028575 Unreliable 711.4858 711.4858 ~ 711.4858
MzDiff: none
PA(18:1(9Z)/22:6(4Z,7Z,10Z,13Z,16Z,19Z)) (BioDeep_00000107299)
Formula: C43H71O8P (746.4886)
0.84 (100%) Macropus giganteus
[UBERON:0001891] midbrain
MSI_000030753 Unreliable 711.4776 711.4776 ~ 711.4776
MzDiff: none
Not Annotated 1.08 (0%) Macropus giganteus
[UBERON:0003027] cingulate cortex
MSI_000030977 Unreliable 711.4932 711.4932 ~ 711.4932
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
0.39 (100%) Macropus giganteus
[UBERON:0003027] cingulate cortex
MSI_000031078 Unreliable 711.4932 711.4932 ~ 711.4932
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
2.55 (100%) Macropus giganteus
[UBERON:0006093] precuneus cortex
MSI_000031163 Unreliable 711.4858 711.4858 ~ 711.4858
MzDiff: none
PA(18:1(9Z)/22:6(4Z,7Z,10Z,13Z,16Z,19Z)) (BioDeep_00000107299)
Formula: C43H71O8P (746.4886)
2.19 (100%) Macropus giganteus
[UBERON:0006093] precuneus cortex
MSI_000044267 Unreliable 711.4919 711.4919 ~ 711.4919
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
0.41 (100%) Rattus norvegicus
[UBERON:0002264] olfactory bulb
MSI_000059968 Unavailable 711.492 711.492 ~ 711.492
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
-0.76 (100%) Mus musculus
[UBERON:0002298] brainstem
MSI_000060627 Unavailable 711.492 711.492 ~ 711.492
MzDiff: none
PA(15:0/22:4(7Z,10Z,13Z,16Z)) (BioDeep_00000107183)
Formula: C40H71O8P (710.4886)
-0.37 (100%) Mus musculus
[UBERON:0002421] hippocampal formation

Found 7 Sample Hits
Metabolite Species Sample
PA(15:0/22:4(7Z,10Z,13Z,16Z))

Formula: C40H71O8P (710.4886)
Adducts: [M+H]+ (Ppm: 5.3)
Rattus norvegicus (Brain)
Spectroswiss - sol_2x_br_2
Resolution: 17μm, 488x193

Description

PA(15:0/22:4(7Z,10Z,13Z,16Z))

Formula: C40H71O8P (710.4886)
Adducts: [M+H]+ (Ppm: 9.1)
Mus musculus (Lung)
image1
Resolution: 40μm, 187x165

Description

Fig. 2 MALDI-MSI data from the same mouse lung tissue analyzed in Fig. 1. A: Optical image of the post-MSI, H&E-stained tissue section. B–D, F–G: Ion images of (B) m/z 796.6855 ([U13C-DPPC+Na]+), (C) m/z 756.5514 ([PC32:0+Na]+), (D) m/z 765.6079 ([D9-PC32:0+Na]+), (F) m/z 754.5359 ([PC32:1+Na]+), and (G) m/z 763.5923 ([D9-PC32:1+Na]+). E, H: Ratio images of (E) [D9-PC32:0+Na]+:[PC32:0+Na]+ and (H) [D9-PC32:1+Na]+:[PC32:1+Na]+. Part-per-million (ppm) mass errors are indicated in parentheses. All images were visualized using total-ion-current normalization and using hotspot removal (high quantile = 99%). DPPC = PC16:0/16:0. U13C-DPPC, universally 13C-labeled dipalmitoyl PC; PC, phosphatidylcholine; MSI, mass spectrometry imaging; H&E, hematoxylin and eosin. Fig 1-3, Fig S1-S3, S5

PA(18:1(9Z)/22:6(4Z,7Z,10Z,13Z,16Z,19Z))

Formula: C43H71O8P (746.4886)
Adducts: [M+H-2H2O]+ (Ppm: 18.4)
Mus musculus (Lung)
image5
Resolution: 40μm, 163x183

Description

Supplementary Figure S8. MALDI-MSI data of mouse lung tissue administered with D9-choline and U 13C-DPPC–containing Poractant alfa surfactant (labels administered 18 h prior to sacrifice). Ion images of (a) m/z 796.6856 ([U13C-DPPC+Na]+), (b) m/z 756.5154 [PC32:0+Na]+ and (c) m/z 765.6079 ([D9-PC32:0+Na]+). (d) Overlay image of [U13C-DPPC+Na]+ (red) and [D9-PC32:0+Na]+ (green). Parts per million (ppm) mass errors are indicated in parentheses. All images were visualised using totalion-current normalisation and using hotspot removal (high quantile = 99%). DPPC = PC16:0/16:0.

PA(15:0/22:4(7Z,10Z,13Z,16Z))

Formula: C40H71O8P (710.4886)
Adducts: [M+H]+ (Ppm: 7.5)
Mus musculus (Lung)
image2
Resolution: 40μm, 550x256

Description

Supplementary Figure S6. Ion distribution images for (a) [PC36:4+Na]+ (m/z 804.5514) and (b) [PC38:6+Na]+ (m/z 828.5515) obtained from mouse lung tissue collected 6 h after administration of D9- choline and U13C-DPPC–containing CHF5633. Parts-per-million (ppm) mass errors are indicated in parentheses. (c) Magnification of the boxed region in (a) with selected bronchiolar regions outlined in white boxes. (d) The corresponding H&E-stained tissue section with the same selected bronchiolar regions outlined in black boxes. These data demonstrate the co-localisation of the polyunsaturated lipids PC36:4 and PC38:6 with the bronchiolar regions of the lung. All MSI images were visualised using total ion current normalisation and hotspot removal (high quantile = 99%).

PA(18:1(9Z)/22:6(4Z,7Z,10Z,13Z,16Z,19Z))

Formula: C43H71O8P (746.4886)
Adducts: [M+H-2H2O]+ (Ppm: 15.5)
Macropus giganteus (Brain)
170321_kangaroobrain-dan3-pos_maxof50.0_med1
Resolution: 50μm, 81x50

Description

Sample information Organism: Macropus giganteus (kangaroo) Organism part: Brain Condition: Wildtype Sample growth conditions: Wild

PA(15:0/22:4(7Z,10Z,13Z,16Z))

Formula: C40H71O8P (710.4886)
Adducts: [M+H]+ (Ppm: 5.6)
Rattus norvegicus (Brain)
2018June2820180628_brain_POS_3s2_validated
Resolution: 17μm, 213x141

Description

All MSI experiments were performed on a hybrid linear ion trap 21 T FT-ICR mass spectrometer at the National High Magnetic Field Laboratory (NHMFL) at Florida State University (Tallahassee, FL). A Velos Pro linear ion trap (Thermo Scientific, San Jose, CA) was combined with NHMFL-designed external linear quadrupole ion trap, quadrupole ion transfer optics and a novel dynamically harmonized ICR cell, which is operated at 7.5 V trapping potential[1]. Briefly, the cell uses 120° cell segments for ion excitation and detection, for improved excitation electric field, detection sensitivity and reduced third harmonic signals[2][3]. The commercial ion source and stacked ring ion guide were replaced with an elevated-pressure MALDI ion source incorporating a dual-ion funnel interface (Spectroglyph LLC, Kennewick, WA) as has been described previously[4]. Voltages within the funnels were 625 kHz, 150 V peak-to-peak (first, high-pressure ion funnel) and 1.2 MHz, 90 V peak-to-peak (second, low-pressure ion funnel). An electric field gradient of ∼10 V/cm was maintained within the dual-funnel system, with a gradient of 100 V/cm between the sample and the funnel inlet. The system was equipped with a Q-switched, frequency-tripled Nd:YLF laser emitting 349 nm light (Explorer One, Spectra Physics, Mountain View, CA). The laser was operated at a repetition rate of 1 kHz and pulse energy of ∼1.2 μJ. Pressure within the ion source was set to 10 mbar in the first ion funnel and 2 mbar in the second ion funnel. MALDI stage motion was synchronized with ion accumulation using the Velos trigger signal indicating commencement of the ion trap injection event, as previously described[4]. The mass spectrometer was operated with an ion injection time of 250 ms and automatic gain control (AGC) was turned off. A transient duration of 3.1 s was used for ultrahigh mass resolving power analyses, resulting in a total time of 4s per pixel. Spectra were obtained in both positive and negative mode, at 100 μm spatial resolution. Total number of pixels per brain section were approximately 22 000 and 24 h of experimental time. A Predator data station was used for ion excitation and detection[5]. Refs: [1] Hendrickson CL, Quinn JP, Kaiser NK, Smith DF, Blakney GT, Chen T, Marshall AG, Weisbrod CR, Beu SC. 21 Tesla Fourier Transform Ion Cyclotron Resonance Mass Spectrometer: A National Resource for Ultrahigh Resolution Mass Analysis. J Am Soc Mass Spectrom. 2015 Sep;26(9):1626-32. doi:10.1007/s13361-015-1182-2. Epub 2015 Jun 20. PMID:26091892. [2] Hendrickson CL, Beu SC, Blakney GT, Kaiser NK, McIntosh DG, Quinn JP, Marshall AG. In Optimized cell geometry for Fourier transform ion cyclotron resonance mass spectrometry, Proceedings of the 57th ASMS Conference on Mass Spectrometry and Allied Topics, Philadelphia, PA, May 31 to June 4; Philadelphia, PA, 2009. [3] Chen T, Beu SC, Kaiser NK, Hendrickson CL. Note: Optimized circuit for excitation and detection with one pair of electrodes for improved Fourier transform ion cyclotron resonance mass spectrometry. Rev Sci Instrum. 2014 Jun;85(6):066107. doi:10.1063/1.4883179. PMID:24985871. [4] Belov ME, Ellis SR, Dilillo M, Paine MRL, Danielson WF, Anderson GA, de Graaf EL, Eijkel GB, Heeren RMA, McDonnell LA. Design and Performance of a Novel Interface for Combined Matrix-Assisted Laser Desorption Ionization at Elevated Pressure and Electrospray Ionization with Orbitrap Mass Spectrometry. Anal Chem. 2017 Jul 18;89(14):7493-7501. doi:10.1021/acs.analchem.7b01168. Epub 2017 Jun 28. PMID:28613836. [5] Blakney GT, Hendrickson CL, Marshall AG. Predator data station: A fast data acquisition system for advanced FT-ICR MS experiments. Int. J. Mass Spectrom. 2011;306 (2-3), 246- 252. doi:10.1016/j.ijms.2011.03.009.

PA(15:0/22:4(7Z,10Z,13Z,16Z))

Formula: C40H71O8P (710.4886)
Adducts: [M+H]+ (Ppm: 11)
Mus musculus (Liver)
Salmonella_final_pos_recal
Resolution: 17μm, 691x430

Description

A more complete and holistic view on host–microbe interactions is needed to understand the physiological and cellular barriers that affect the efficacy of drug treatments and allow the discovery and development of new therapeutics. Here, we developed a multimodal imaging approach combining histopathology with mass spectrometry imaging (MSI) and same section imaging mass cytometry (IMC) to study the effects of Salmonella Typhimurium infection in the liver of a mouse model using the S. Typhimurium strains SL3261 and SL1344. This approach enables correlation of tissue morphology and specific cell phenotypes with molecular images of tissue metabolism. IMC revealed a marked increase in immune cell markers and localization in immune aggregates in infected tissues. A correlative computational method (network analysis) was deployed to find metabolic features associated with infection and revealed metabolic clusters of acetyl carnitines, as well as phosphatidylcholine and phosphatidylethanolamine plasmalogen species, which could be associated with pro-inflammatory immune cell types. By developing an IMC marker for the detection of Salmonella LPS, we were further able to identify and characterize those cell types which contained S. Typhimurium. [dataset] Nicole Strittmatter. Holistic Characterization of a Salmonella Typhimurium Infection Model Using Integrated Molecular Imaging, metabolights_dataset, V1; 2022. https://www.ebi.ac.uk/metabolights/MTBLS2671.