在BioDeep NovoCell知识数据库中,参考离子总共被划分为4个级别。
  • Confirmed: 这个参考离子已经通过手动审计得到确认和验证。
  • Reliable: 这个参考离子可能在特定的解剖组织环境中高度保守。
  • Unreliable: 这个参考离子具有较高的排名价值,但缺乏可重复性。
  • Unavailable: 由于排名价值低且缺乏可重复性,这个参考离子不应用于注释。

Found 6 Reference Ions Near m/z 740.5473
NovoCell ID m/z Mass Window Metabolite Ranking Anatomy Context
MSI_000052326 Unreliable 740.5389 740.5389 ~ 740.5389
MzDiff: none
Not Annotated 2.19 (0%) Homo sapiens
[UBERON:0001052] rectum
MSI_000053053 Unreliable 740.5511 740.5511 ~ 740.5511
MzDiff: none
PC(18:2(9Z,12Z)/16:0) (BioDeep_00000029408)
Formula: C42H80NO8P (757.5621)
3.02 (100%) DESI
[NOVOCELL:BACKGROUND] blank
MSI_000026496 Unreliable 740.557 740.557 ~ 740.557
MzDiff: none
PC(18:3(6Z,9Z,12Z)/P-16:0) (BioDeep_00000029459)
Formula: C42H78NO7P (739.5516)
1.79 (100%) Mus musculus
[UBERON:0002048] lung
MSI_000026573 Unreliable 740.5489 740.5489 ~ 740.5489
MzDiff: none
Not Annotated 1.79 (0%) Mus musculus
[UBERON:0002048] lung
MSI_000026901 Unreliable 740.5541 740.5541 ~ 740.5541
MzDiff: none
PC(18:3(6Z,9Z,12Z)/P-16:0) (BioDeep_00000029459)
Formula: C42H78NO7P (739.5516)
1.78 (100%) Mus musculus
[UBERON:0002048] lung
MSI_000027901 Unreliable 740.5555 740.5555 ~ 740.5555
MzDiff: none
PC(18:3(6Z,9Z,12Z)/P-16:0) (BioDeep_00000029459)
Formula: C42H78NO7P (739.5516)
2.01 (100%) Mus musculus
[UBERON:0002048] lung

Found 8 Sample Hits
Metabolite Species Sample
PC(16:0/18:2)

Formula: C42H80NO8P (757.5621)
Adducts: [M+H-H2O]+ (Ppm: 2.1)
Bathymodiolus (epithelial host cells)
MPIBremen_Bputeoserpentis_MALDI-FISH_DHB_233x233pixel_3um_mz400-1200_240k@200
Resolution: 3μm, 233x233

Description

The Bathymodiolus puteoserpentis specimen used for high resolution AP-MALDI-MSI was collected during the RV Meteor M126 cruise in 2016 at the Logatchev hydrothermal vent field on the Mid-Atlantic Ridge. The specimen was retrieved with the MARUM-Quest remotely operated vehicle (ROV) at the Irina II vent site at 3038 m depth, 14°45’11.01”N and 44°58’43.98”W, and placed in an insulated container to prevent temperature changes during recovery. Gills were dissected from the mussel as soon as brought on board after ROV retrieval, submerged in precooled 2% w/v carboxymethyl cellulose gel (CMC, Mw ~ 700,000, Sigma-Aldrich Chemie GmbH) and snap-frozen in liquid N2. Samples were stored at -80 °C until use.
The CMC-embedded gills were cross-sectioned at 10 µm thickness with a cryostat (Leica CM3050 S, Leica Biosystems Nussloch GmbH) at a chamber temperature of -35 °C and object holder at -22 °C. Individual sections were thaw-mounted onto coated Polysine slides (Thermo Scientific) and subsequently frozen in the cryostat chamber. Slides with tissue sections were stored in slide containers with silica granules, to prevent air moisture condensation on the tissue upon removal from the freezer. Before AP-MALDI matrix application, the sample was warmed to room temperature under a dry atmosphere in a sealed slide container (LockMailer microscope slide jar, Sigma-Aldrich, Steinheim, Germany), filled with silica granules (Carl Roth GmbH) to avoid condensation on the cold glass slide. The sample glass slide was marked with white paint around the tissue for orientation during image acquisition as previously described[1]. Additionally, optical images of the tissue section were acquired with a digital microscope (VHX-5000 Series, Keyence, Neu-Isenburg, Germany) prior to matrix application. To apply the matrix, we used an ultrafine pneumatic sprayer system with N2 gas (SMALDIPrep, TransMIT GmbH, Giessen, Germany)[2], to deliver 100 μl of a 30 mg/ml solution of 2,5-dihydroxybenzoic acid (DHB; 98% 574 purity, Sigma-Aldrich, Steinheim, Germany) dissolved in acetone/water (1:1 v/v) containing 0.1% trifluoroacetic acid (TFA). To locate the field of view and facilitate laser focusing, a red marker was applied adjacent to the matrix-covered tissue section. Ref: [1] Kaltenpoth M, Strupat K, Svatoš A Linking metabolite production to taxonomic identity in environmental samples by (MA)LDI-FISH. ISME J. 2016 Feb;10(2):527-31. doi: 10.1038/ismej.2015.122. PMID:26172211 [2] Kompauer M, Heiles S, Spengler B. Atmospheric pressure MALDI mass spectrometry imaging of tissues and cells at 1.4-μm lateral resolution. Nat Methods. 2017 Jan;14(1):90-96. doi: 10.1038/nmeth.4071. PMID:27842060
High-resolution AP-MALDI-MSI measurements were carried out at an experimental ion source setup [1][2], coupled to a Fourier transform orbital trapping mass spectrometer (Q Exactive HF, Thermo Fisher Scientific GmbH, Bremen, Germany). The sample was rastered with 233 x 233 laser spots with a step size of 3 µm without oversampling, resulting in an imaged area of 699 x 699 µm. AP-MALDI-MSI measurements were performed in positive mode for a mass detection range of 400–1200 Da and a mass resolving power of 240,000 (at 200 m/z). After AP-MALDI-MSI, the measured sample surface was recorded using a stereomicroscope (SMZ25, Nikon, Düssedorf, Germany). Ref: [1] Kompauer M, Heiles S, Spengler B. Atmospheric pressure MALDI mass spectrometry imaging of tissues and cells at 1.4-μm lateral resolution. Nat Methods. 2017 Jan;14(1):90-96. doi: 10.1038/nmeth.4071. PMID:27842060 [2] Kompauer M, Heiles S, Spengler B. Autofocusing MALDI mass spectrometry imaging of tissue sections and 3D chemical topography of nonflat surfaces. Nat Methods. 2017 Dec;14(12):1156-1158. doi:10.1038/nmeth.4433. PMID:28945703

PE(P-18:0/22:6(4Z,7Z,10Z,13Z,16Z,19Z))

Formula: C45H78NO7P (775.5516)
Adducts: [M+H-2H2O]+ (Ppm: 16.2)
Mus musculus (Lung)
image1
Resolution: 40μm, 187x165

Description

Fig. 2 MALDI-MSI data from the same mouse lung tissue analyzed in Fig. 1. A: Optical image of the post-MSI, H&E-stained tissue section. B–D, F–G: Ion images of (B) m/z 796.6855 ([U13C-DPPC+Na]+), (C) m/z 756.5514 ([PC32:0+Na]+), (D) m/z 765.6079 ([D9-PC32:0+Na]+), (F) m/z 754.5359 ([PC32:1+Na]+), and (G) m/z 763.5923 ([D9-PC32:1+Na]+). E, H: Ratio images of (E) [D9-PC32:0+Na]+:[PC32:0+Na]+ and (H) [D9-PC32:1+Na]+:[PC32:1+Na]+. Part-per-million (ppm) mass errors are indicated in parentheses. All images were visualized using total-ion-current normalization and using hotspot removal (high quantile = 99%). DPPC = PC16:0/16:0. U13C-DPPC, universally 13C-labeled dipalmitoyl PC; PC, phosphatidylcholine; MSI, mass spectrometry imaging; H&E, hematoxylin and eosin. Fig 1-3, Fig S1-S3, S5

PC(18:3(6Z,9Z,12Z)/P-16:0)

Formula: C42H78NO7P (739.5516)
Adducts: [M+H]+ (Ppm: 5.6)
Mus musculus (Lung)
image3
Resolution: 40μm, 146x190

Description

Fig. 4 MALDI-MSI data of mouse lung tissue after administration with D9-choline and U13C-DPPC–containing Poractant alfa surfactant (labels administered 12 h prior to tissue collection). Ion images of (A) m/z 796.6856 ([U13C-DPPC+Na]+), (B) m/z 756.5154 [PC32:0+Na]+), and (C) m/z 765.6079 ([D9-PC32:0+Na]+). D: Overlay image of [U13C-PC32:0+Na]+ (red) and [D9-PC32:0+Na]+ (green). Part-per-million (ppm) mass errors are indicated in parentheses. All images were visualized using total-ion-current normalization and using hotspot removal (high quantile = 99%). DPPC = PC16:0/16:0. MSI, mass spectrometry imaging; PC, phosphatidylcholine; U13C-DPPC, universally 13C-labeled dipalmitoyl PC.

m/z_740.5489

Formula: - (n/a)
Adducts: (Ppm: 0)
Mus musculus (Lung)
image4
Resolution: 40μm, 162x156

Description

Fig 6c Fig. 6 MALDI-MSI of U13C-PC16:0/16:0 acyl chain remodeling. A: Averaged MALDI mass spectrum from lung tissue collected from mice euthanized 12 h after administration of D9-choline and U13C-DPPC–containing Poractant alfa surfactant. The ion at m/z 828.6321 is assigned as the [M+Na]+ ion of 13C24-PC16:0_20:4 formed by acyl remodeling of U13C-PC16:0/16:0. The “NL” value refers to the intensity of the base peak in the full range MS1 spectrum. B: MS/MS spectrum of precursor ions at m/z 828.5 ± 0.5 with fragment ions originating from [13C24-PC16:0_20:4+Na]+ annotated. Part-per-million (ppm) mass errors are provided in parentheses. C, D: MALDI-MSI data of [U13C-DPPC+Na]+ (blue), [PC36:4+Na]+ (green) and [13C24-PC16:0_20:4+Na]+ (red) in lung tissue collected from mice (C) 12 h and (D) 18 h after label administration. All images were visualized using total-ion-current normalization and hotspot removal (high quantile = 99%). MS/MS, tandem mass spectrometry; MSI, mass spectrometry imaging; PC, phosphatidylcholine; U13C-DPPC, universally 13C-labeled dipalmitoyl PC.

PC(18:3(6Z,9Z,12Z)/P-16:0)

Formula: C42H78NO7P (739.5516)
Adducts: [M+H]+ (Ppm: 4)
Mus musculus (Liver)
Salmonella_final_pos_recal
Resolution: 17μm, 691x430

Description

A more complete and holistic view on host–microbe interactions is needed to understand the physiological and cellular barriers that affect the efficacy of drug treatments and allow the discovery and development of new therapeutics. Here, we developed a multimodal imaging approach combining histopathology with mass spectrometry imaging (MSI) and same section imaging mass cytometry (IMC) to study the effects of Salmonella Typhimurium infection in the liver of a mouse model using the S. Typhimurium strains SL3261 and SL1344. This approach enables correlation of tissue morphology and specific cell phenotypes with molecular images of tissue metabolism. IMC revealed a marked increase in immune cell markers and localization in immune aggregates in infected tissues. A correlative computational method (network analysis) was deployed to find metabolic features associated with infection and revealed metabolic clusters of acetyl carnitines, as well as phosphatidylcholine and phosphatidylethanolamine plasmalogen species, which could be associated with pro-inflammatory immune cell types. By developing an IMC marker for the detection of Salmonella LPS, we were further able to identify and characterize those cell types which contained S. Typhimurium. [dataset] Nicole Strittmatter. Holistic Characterization of a Salmonella Typhimurium Infection Model Using Integrated Molecular Imaging, metabolights_dataset, V1; 2022. https://www.ebi.ac.uk/metabolights/MTBLS2671.

PC(18:2(9Z,12Z)/16:0)

Formula: C42H80NO8P (757.5621)
Adducts: [M+H-H2O]+ (Ppm: 10.4)
Homo sapiens (colorectal adenocarcinoma)
80TopL, 50TopR, 70BottomL, 60BottomR-profile
Resolution: 17μm, 137x136

Description

The human colorectal adenocarcinoma sample was excised during a surgical operation performed at the Imperial College Healthcare NHS Trust. The sample and procedures were carried out in accordance with ethical approval (14/EE/0024).

PC(18:3(6Z,9Z,12Z)/P-16:0)

Formula: C42H78NO7P (739.5516)
Adducts: [M+H]+ (Ppm: 17.6)
Homo sapiens (colorectal adenocarcinoma)
520TopL, 490TopR, 510BottomL, 500BottomR-profile
Resolution: 17μm, 147x131

Description

The human colorectal adenocarcinoma sample was excised during a surgical operation performed at the Imperial College Healthcare NHS Trust. The sample and procedures were carried out in accordance with ethical approval (14/EE/0024).

PC(P-16:0/18:1(12Z)-2OH(9,10))

Formula: C42H82NO9P (775.5727)
Adducts: [M+H-2H2O]+ (Ppm: 15.6)
Homo sapiens (NA)
160TopL,130TopR,150BottomL,140BottomR-profile
Resolution: 17μm, 142x136

Description