在BioDeep NovoCell知识数据库中,参考离子总共被划分为4个级别。
  • Confirmed: 这个参考离子已经通过手动审计得到确认和验证。
  • Reliable: 这个参考离子可能在特定的解剖组织环境中高度保守。
  • Unreliable: 这个参考离子具有较高的排名价值,但缺乏可重复性。
  • Unavailable: 由于排名价值低且缺乏可重复性,这个参考离子不应用于注释。

Found 6 Reference Ions Near m/z 772.4862
NovoCell ID m/z Mass Window Metabolite Ranking Anatomy Context
MSI_000011394 Unreliable 772.4942 772.4942 ~ 772.4942
MzDiff: none
Kemptide (BioDeep_00000180259)
Formula: C32H61N13O9 (771.4715)
0.58 (100%) Mus musculus
[UBERON:0012378] muscle layer of urinary bladder
MSI_000011418 Unreliable 772.4862 772.4862 ~ 772.4862
MzDiff: none
PS(14:0/20:3(5Z,8Z,11Z)-O(14R,15S)) (BioDeep_00000185444)
Formula: C40H70NO11P (771.4686)
0.45 (100%) Mus musculus
[UBERON:0012378] muscle layer of urinary bladder
MSI_000000090 Unreliable 772.4862 772.4862 ~ 772.4862
MzDiff: none
PS(14:0/20:3(5Z,8Z,11Z)-O(14R,15S)) (BioDeep_00000185444)
Formula: C40H70NO11P (771.4686)
2.08 (100%) Mus musculus
[CL:0000066] epithelial cell
MSI_000000095 Unreliable 772.4942 772.4942 ~ 772.4942
MzDiff: none
Kemptide (BioDeep_00000180259)
Formula: C32H61N13O9 (771.4715)
2.07 (100%) Mus musculus
[CL:0000066] epithelial cell
MSI_000030320 Unreliable 772.4896 772.4896 ~ 772.4896
MzDiff: none
Kemptide (BioDeep_00000180259)
Formula: C32H61N13O9 (771.4715)
1.94 (100%) Macropus giganteus
[UBERON:0003027] cingulate cortex
MSI_000043942 Unreliable 772.4789 772.4789 ~ 772.4789
MzDiff: none
Kemptide (BioDeep_00000180259)
Formula: C32H61N13O9 (771.4715)
2.57 (100%) Rattus norvegicus
[UBERON:0002264] olfactory bulb

Found 3 Sample Hits
Metabolite Species Sample
PS(14:0/20:3(5Z,8Z,11Z)-O(14R,15S))

Formula: C40H70NO11P (771.4686)
Adducts: [M+H]+ (Ppm: 13.3)
Mus musculus (Urinary bladder)
HR2MSI_mouse_urinary_bladder - S096
Resolution: 10μm, 260x134

Description

Mass spectrometry imaging of phospholipids in mouse urinary bladder (imzML dataset)
The spatial distribution of phospholipids in a tissue section of mouse urinary bladder was analyzed by MALDI MS imaging at 10 micrometer pixel size with high mass resolution (using an LTQ Orbitrap mass spectrometer).

R, ö, mpp A, Guenther S, Schober Y, Schulz O, Takats Z, Kummer W, Spengler B, Histology by mass spectrometry: label-free tissue characterization obtained from high-accuracy bioanalytical imaging. Angew Chem Int Ed Engl, 49(22):3834-8(2010)

Fig. S2: Single ion images of compounds shown in Fig. 1A-B : (upper left to lower right) m/z = 743.5482 (unknown), m/z = 741.5307 (SM (16:0), [M+K]+), m/z = 798.5410 (PC (34:1), [M+K]+), m/z = 616.1767 (heme b, M+), m/z = 772.5253 (PC (32:0), [M+K]+).

Stability of determined mass values was in the range of +/- 1 ppm over 22 hours of measurement (Fig. S4), with a standard deviation of 0.56 ppm. Accuracy data were obtained during tissue scanning experiments by monitoring the mass signal at nominal mass 798. The internal lock mass function of the Orbitrap instrument was used for automatic calibration during imaging measurements, using the known matrix-related ion signals at m/z = 137.0233, m/z = 444.0925 and m/z = 716.1246.

Kemptide

Formula: C32H61N13O9 (771.4715)
Adducts: [M+H]+ (Ppm: 14)
Macropus giganteus (Brain)
170321_kangaroobrain-dan3-pos_maxof50.0_med1
Resolution: 50μm, 81x50

Description

Sample information Organism: Macropus giganteus (kangaroo) Organism part: Brain Condition: Wildtype Sample growth conditions: Wild

PE-NMe(18:4(6Z,9Z,12Z,15Z)/20:5(5Z,8Z,11Z,14Z,17Z))

Formula: C44H70NO8P (771.4839)
Adducts: [M+H]+ (Ppm: 5.8)
Homo sapiens (colorectal adenocarcinoma)
520TopL, 490TopR, 510BottomL, 500BottomR-profile
Resolution: 17μm, 147x131

Description

The human colorectal adenocarcinoma sample was excised during a surgical operation performed at the Imperial College Healthcare NHS Trust. The sample and procedures were carried out in accordance with ethical approval (14/EE/0024).