在BioDeep NovoCell知识数据库中,参考离子总共被划分为4个级别。
  • Confirmed: 这个参考离子已经通过手动审计得到确认和验证。
  • Reliable: 这个参考离子可能在特定的解剖组织环境中高度保守。
  • Unreliable: 这个参考离子具有较高的排名价值,但缺乏可重复性。
  • Unavailable: 由于排名价值低且缺乏可重复性,这个参考离子不应用于注释。

Found 3 Reference Ions Near m/z 546.0636
NovoCell ID m/z Mass Window Metabolite Ranking Anatomy Context
MSI_000011302 Unreliable 546.0636 546.0636 ~ 546.0636
MzDiff: none
dTDP-4-oxo-6-deoxy-D-glucose (BioDeep_00000014418)
Formula: C16H24N2O15P2 (546.0652)
1.22 (100%) Mus musculus
[UBERON:0012378] muscle layer of urinary bladder
MSI_000009492 Unavailable 546.0636 546.0636 ~ 546.0636
MzDiff: none
dTDP-4-oxo-6-deoxy-D-glucose (BioDeep_00000014418)
Formula: C16H24N2O15P2 (546.0652)
-0.55 (100%) Mus musculus
[UBERON:0004645] urinary bladder urothelium
MSI_000000896 Unavailable 546.0636 546.0636 ~ 546.0636
MzDiff: none
dTDP-4-oxo-6-deoxy-D-glucose (BioDeep_00000014418)
Formula: C16H24N2O15P2 (546.0652)
-0.76 (100%) Mus musculus
[CL:0000066] epithelial cell

Found 2 Sample Hits
Metabolite Species Sample
dTDP-4-oxo-6-deoxy-D-glucose

Formula: C16H24N2O15P2 (546.0652)
Adducts: [M]+ (Ppm: 1.9)
Mus musculus (Urinary bladder)
HR2MSI_mouse_urinary_bladder - S096
Resolution: 10μm, 260x134

Description

Mass spectrometry imaging of phospholipids in mouse urinary bladder (imzML dataset)
The spatial distribution of phospholipids in a tissue section of mouse urinary bladder was analyzed by MALDI MS imaging at 10 micrometer pixel size with high mass resolution (using an LTQ Orbitrap mass spectrometer).

R, ö, mpp A, Guenther S, Schober Y, Schulz O, Takats Z, Kummer W, Spengler B, Histology by mass spectrometry: label-free tissue characterization obtained from high-accuracy bioanalytical imaging. Angew Chem Int Ed Engl, 49(22):3834-8(2010)

Fig. S2: Single ion images of compounds shown in Fig. 1A-B : (upper left to lower right) m/z = 743.5482 (unknown), m/z = 741.5307 (SM (16:0), [M+K]+), m/z = 798.5410 (PC (34:1), [M+K]+), m/z = 616.1767 (heme b, M+), m/z = 772.5253 (PC (32:0), [M+K]+).

Stability of determined mass values was in the range of +/- 1 ppm over 22 hours of measurement (Fig. S4), with a standard deviation of 0.56 ppm. Accuracy data were obtained during tissue scanning experiments by monitoring the mass signal at nominal mass 798. The internal lock mass function of the Orbitrap instrument was used for automatic calibration during imaging measurements, using the known matrix-related ion signals at m/z = 137.0233, m/z = 444.0925 and m/z = 716.1246.

Calcium lignosulfonate

Formula: C20H24CaO10S2 (528.0437)
Adducts: [M+NH4]+ (Ppm: 6.8)
Mus musculus (Lung)
image3
Resolution: 40μm, 146x190

Description

Fig. 4 MALDI-MSI data of mouse lung tissue after administration with D9-choline and U13C-DPPC–containing Poractant alfa surfactant (labels administered 12 h prior to tissue collection). Ion images of (A) m/z 796.6856 ([U13C-DPPC+Na]+), (B) m/z 756.5154 [PC32:0+Na]+), and (C) m/z 765.6079 ([D9-PC32:0+Na]+). D: Overlay image of [U13C-PC32:0+Na]+ (red) and [D9-PC32:0+Na]+ (green). Part-per-million (ppm) mass errors are indicated in parentheses. All images were visualized using total-ion-current normalization and using hotspot removal (high quantile = 99%). DPPC = PC16:0/16:0. MSI, mass spectrometry imaging; PC, phosphatidylcholine; U13C-DPPC, universally 13C-labeled dipalmitoyl PC.